Wheatstone Bridge, Kelvin Bridge, Standard,
Resistance, Microohmmeter, Ohmmeter, Low Resistance meter, Platinum
Thermometer, Transformer Coil Ratiometer, Resistance, LCR |
 |
Thermometer Bridge, Primary Standard,
Thermometer, Standard Temperature Resistance Standard, Precision
Thermometer,
Resistor Standard, Resistance Decade, Milli Ohmmeter, LCR |
|
PRECISION
RESISTANCE THERMOMETRY INSTRUMENTS |
|
|
|

|
|
|
Senator 5840D
Thermometer Bridge. Multi-range
Automatic Resistance Thermometer Bridge.
5840E2
AC. Thermometer Bridge.
High precision programmable AC Resistance Bridge.
5885 Precision Digital Thermometer with PRT and Thermocouple
inputs.
5187SA Primary Standard Platinum Resistance Thermometer.
High Accuracy Reference Thermometer. 5187L
Helium Filled Platinum Sheath Thermometer.
5840 Selector switches.
Thermometer Selector Switches for manual or remote operation.
5648 Temperature Controlled Enclosure.36
°C +/- 0.1 °C
5882/3 Envoy & Premier Programmable Resistance Thermometer
Bridges. 5884 System Thermometer.
|
|
RESISTANCE
MEASURING INSTRUMENTS |
|
|
|
5890
Micro-Ohmmeter with Temp
Compensation. Range 1.9mΩ to 1900 Ω, 0.05% accuracy
5895
Transformer Micro-Ohmmeter.10 mΩ
to 100 Ω full scale in 6 ranges
nominal 0.1% accuracy
5893
Battery Micro-Ohmmeter.600 mΩ
to 60 Ω full scale in 6 ranges Nominal 0.15% accuracy
5897
High Current (100A) Portable
Micro-Ohmmeter. Range 400mΩ to 40Ω, 0.2% accuracy
5898
High Current (200A) Portable
Micro-Ohmmeter. Range 600mΩ to 6Ω, 0.2% accuracy
5896
High Current Micro-Ohmmeter.1mΩ to 100Ω full
scale
in 6 ranges Nominal 0.1% accuracy
QJ84 Digital Resistance Test Instrument.20mΩ
to 20 kΩ
full scale.
0.05% accuracy.
QJ23E Portable Wheatstone Bridge. Resistance
Measurements. Range
1Ω
to 9.999MΩ
0.1 to 0.2 % accuracy
QJ49E Portable
Precision Wheatstone Bridge. Range 1Ω
to 1.1111MΩ.
0.05 % accuracy
QJ31E Portable Wheatstone Kelvin
Bridge. Range 10Ω
to 1MΩ
(Wheatstone)
0.0001Ω to 100Ω
(Kelvin)
0.1 % accuracy.
QJ42E Portable
Double Wheatstone Kelvin Bridge. Range
0.0001Ω to 11Ω. Accuracy typically 1.0%.
QJ57E Portable
Precision DC Kelvin Bridge. Range 10-8Ω to 1111.1Ω.
Accuracy 0.03%
|
|
STANDARD RESISTOR, CAPACITANCE,
INDUCTANCE DC SHUNTS AND CELL
|
|
|
|
|
|
5685A Wilkins
Standard Resistor, 1 ohm, 10 ohm, 25 ohm and 100 ohms. Standard Resistor.
5685B Wilkins
Standard Resistor, 1 Kohm, 10 Kohm Wilkins type Standard Resistor.
5615 High Resistance Standards, 100
Kohm, 1Mohm, 10 Mohm. Resistor Standard.
5686 Low Value Resistance Standard. 0.001
ohm, 0.01 ohm, 0.1 ohm. Resistor Standard.
1660 Low Cost Standard Resistor.
1659 Non-Inductive Resistors.
10000, 5000, 1000, 200, 100, 10, 5, 2, 1, 0.5, 0.2 ohm.
1682 Precision Non-Inductive Standard Resistors.
0.2, 0.1, 0.05. Standard Resistor. High Current.
3111 Precision Non-Inductive Standard Resistors.
0.02, 0.01, 0.005 ohm. Oil Filled. High Current.
4737B Specialist Standard for the calibration of Micro-Ohmmeters.
5648 Temperature Controlled Enclosure.
4638 Air cooled DC Shunts Standards. Range 1.5 to 2,000 Amperes.
4640 Air cooled DC Shunts. Standards. Range 50 Amp to 1000
Amp.
2276 Air cooled DC Shunts Standards. Up to 20,000 Amperes.
ZX74
Decade
Resistance Boxes (0.01% accuracy), Decade Resistance Boxes (0.1% accuracy).
ZX90
Decade
Resistance Boxes (0.01% accuracy), Decade Resistance Boxes (0.1% accuracy).
4720 Nine Decade High Resistance Boxes for the checking and calibration of
Insulation Testers at voltages up to 5000V.
4721 Single, High Resistance Decade Box for the checking and calibration of
Insulation Testers at voltages up to 5000V.
|
|
EQUIPMENT STANDARDS
|
|
|
|
5560K Precision Two Stage Inductive Voltage Divider.
The 8 Dial Inductive Voltage Divider
5573 Precision High Voltage Resistance Divider.
Resistance of 1000 Ohms per Volt and is
made in 50 kV sections.
|
|
RESISTANCE DECADES AND BOXES
|
|
|
|
ZX74 Series- Decade
Resistance Boxes. Accuracy 0.01%. Decade Resistor.
ZX90 Series- Decade
Resistance Boxes. Accuracy 0.1%.Decade Resistor.
4720 Nine Decade High Resistance Boxes for the checking and calibration of
Insulation Testers at voltages up to 5000V.
4721 Single, High Resistance Decade Box for the checking and calibration of
Insulation Testers at voltages up to 5000V.
|
|
TRANSFORMER TEST EQUIPMENT
|
|
|
|
|
|
5895 Transformer
Micro-Ohmmeter (10Amp).Resistance
measurement requirement of BS171 Part 2 or Part 1 IEC 76-5.
5896C Transformer Micro-Ohmmeter (25Amp).Ohmmeter will measure the D.C. resistance of power
transformers and other electrical devices
5897 High Current (100Amp) Portable Micro-Ohmmeter.4 terminal measurement.
Basic accuracy of 0.2% and an overall resistance range of 0.1 mΩ
to 40 Ω.
5898 High Current (200A) Portable Micro-Ohmmeter.4 terminal measurement.
Basic accuracy of 0.2% and an overall resistance range of 0.1 mΩ to 6 Ω.
4167D Digital Transformer Ratiometer.
Direct Ratio Reading from 1:1 to 9990:1
4167P Portable Transformer Ratiometer.
Measures the
transformation ratio of large
transformers
4167DH Automatic Transformer Ratiometer.
PC interfaces (RS232; IEEE488; RS385; RS422)
5867F Portable Quality Tester.
Shunted and shorted turns, Insulation Resistance breakdown.
|
|
COIL TEST EQUIPMENT
|
|
|
|
|
|
9600
Coil Turns Counter Readout Unit.
9601, 9602, 9603
Coil Turns Counter Platforms.
5863 Shorted Turn Tester.
5867 Portable Quality Tester.
Shunted and shorted turns, Insulation Resistance breakdown.
5846 Transformer Iron Tester.
|
|
PRECISION STRAIN MEASURING INSTRUMENTS
|
|
|
|
8691 Sterling-Single Channel Strain Meter.
8692 Sovereign-Ten Channel Strain Meter.
|
|
WHEATSTONE KELVIN BRIDGES
|
|
|
QJ23E Portable Wheatstone Bridge. Resistance
Measurements. Range
1Ω
to 9.999MΩ
0.1 to 0.2 % accuracy
QJ49E Portable
Precision Wheatstone Bridge. Range 1Ω
to 1.1111MΩ.
0.05 % accuracy
QJ31E Portable Wheatstone Kelvin
Bridge. Range 10Ω
to 1MΩ
(Wheatstone)
0.0001W to 100W
(Kelvin) 0.1
% accuracy.
QJ42E Portable
Double Wheatstone Kelvin Bridge. Range
0.0001Ω to 11Ω.
Accuracy typically 1.0%.
QJ57E Portable
Precision DC Kelvin Bridge. Range 10-8Ω
to 1111.1Ω.
Accuracy
0.03%
|
|
SPECIALIST ELECTRONICS EQUIPMENT
|
|
|
|
5762
High Resistance Cable Fault locator.
5762N
High Resistance Cable Fault locator.
5860A Electronic Lift Overload Indicator.
|
|
SUBMARINE CABLE TEST
EQUIPMENT
|
|
|
5902 Long
Haul Submarine Cable Test Set
5930, 5931
Submarine Cable Survey System
5910
Portable Short haul Submarine Cable Test Set
5910R
Rack Mount Short haul Submarine Cable Test Set
5915
Electroding Generator
5916
Electroding Detector
5917
Beach Probe
5918
Battery Powered Portable Electroding Detector
5901C
Submarine Cable DC Test Set
5941
Cable Termination Unit
5906A, 5906B
Specialist Standard for the calibration of Model 5902 Submarine Cable
Test Set
|
|
|