Wheatstone Bridge, Kelvin Bridge, Standard,
Resistance, Microohmmeter, Ohmmeter, Low Resistance meter, Platinum
Thermometer,
Transformer Coil Ratiometer, Resistance, LCR Thermometer Bridge, Primary Standard,
Thermometer, Standard Temperature Resistance Standard, Precision
Thermometer,
Resistor Standard, Resistance Decade, Milli Ohmmeter, LCR |
|
|
PRECISION
RESISTANCE THERMOMETRY INSTRUMENTS
|
|
|
|

|
|
|
5840E2
AC. Thermometer Bridge.
High precision programmable AC Resistance Bridge.
5885
Precision Digital Thermometer with PRT and Thermocouple
inputs.
5187SA Primary Standard Platinum Resistance Thermometer.
High Accuracy Reference Thermometer.
5187L
Helium Filled Platinum Sheath Thermometer.
5840
Selector switches.
Thermometer Selector Switches for manual or remote operation.
5648
Temperature Controlled Enclosure.
Temperature 36
°C +/- 0.1 °C
|
RESISTANCE
MEASURING INSTRUMENTS
|
|
|
|
5893
Battery Micro-Ohmmeter. 600 mΩ
to 60 Ω full scale in 6 ranges Nominal 0.15% accuracy
5894
Milli-Ohmmeter.10 mΩ
to 100 kΩ full scale in 9 ranges
nominal 0.03% accuracy
5895
Transformer Micro-Ohmmeter.10 mΩ
to 100 Ω full scale in 6 ranges
nominal 0.1% accuracy
5897
High Current (100A) Portable
Micro-Ohmmeter. Range 400mΩ to 40Ω, 0.2% accuracy
5898
High Current (200A) Portable
Micro-Ohmmeter. Range 600mΩ to 6Ω, 0.2% accuracy
5896C
High Current Micro-Ohmmeter.1mΩ to 100Ω full
scale
in 6 ranges Nominal 0.1% accuracy
QJ23E
Wheatstone Bridge. Resistance Bridge. Range
1Ω
to 9.999MΩ
0.1 to 0.2 % accuracy
QJ49E
Portable
Precision Wheatstone Bridge. Range 1Ω
to 1.1111MΩ.
0.05 % accuracy
QJ31E Portable Wheatstone Kelvin
Bridge. Range 10Ω
to 1MΩ
and
0.0001Ω to 100Ω
0.1 % accuracy.
QJ42E Portable
Double Wheatstone Kelvin Bridge. Range
0.0001Ω to 11Ω. Accuracy typically 1.0%.
QJ57E Portable
Precision DC Kelvin Bridge. Range 10-8Ω to 1111.1Ω.
Accuracy 0.03%
|
STANDARD RESISTOR, CAPACITANCE,
INDUCTANCE DC SHUNTS
|
|
|
|
|
|
5685A Wilkins
Standard Resistor, 1 ohm, 10 ohm, 25 ohm and 100 ohms. Standard Resistor.
5685B
Wilkins
Standard Resistor, 1 Kohm, 10 Kohm Wilkins type Standard Resistor.
5615 High Resistance Standards, 100 Kohm, 1Mohm, 10 Mohm. Resistor Standard.
5686 Low Value Resistance Standard. 0.001
ohm, 0.01 ohm, 0.1 ohm. Resistor Standard.
1660
Low Cost Standard Resistor.
1659 Non-Inductive Resistor.
10000, 5000, 1000, 200, 100, 10, 5, 2, 1, 0.5, 0.2 ohm.
1682
Precision Non-Inductive Standard Resistor.
0.2, 0.1, 0.05. Standard Resistor. High Current.
3111
Precision Non-Inductive Standard Resistors.
0.02, 0.01, 0.005 ohm. Oil Filled. High Current.
4737B
Standard resistance box for the calibration of Micro-Ohmmeters.
5648
Temperature Controlled Enclosure.
4638
Air cooled DC Shunt. Current Shunt Standard. Range 1.5 to 2,000 Amperes.
4640
Air cooled DC Shunt. Current Shunt Standard. Range 50 Amp to 1000
Amp.
2276
Air cooled DC Shunt. Current Shunt Standard. Up to 20,000 Amperes.
ZX74
Decade
Resistance. Resistance Box (0.01% accuracy), Decade Resistance Boxes
(0.1% accuracy).
ZX90
Decade
Resistance. Resistance Box. Decade Resistance Boxes (0.01%
and 0.1% accuracy).
4720
Resistance Decade. High voltage, High Resistance
Decade Box Voltages up to 5000V.
4721
High voltage resistance decade. Single, High Resistance Decade Box.
|
RESISTANCE DECADES AND BOXES
|
|
|
|
ZX74
Decade
Resistance. Resistance Box. Accuracy 0.01%. Decade Resistor.
ZX90
Decade
Resistance. Resistance Boxes. Accuracy 0.1%.Decade Resistor.
4720
Resistance Decade. High voltage, High Resistance
Decade Box Voltages up to 5000V.
4721
High voltage resistance decade. Single, High Resistance Decade Box.
|
TRANSFORMER TEST EQUIPMENT
|
|
|
|
|
|
5895
Transformer
Micro-Ohmmeter (10Amp).
Transformer Resistance
measurement.
5896C
Transformer Micro-Ohmmeter (25Amp). Ohmmeter
will measure the D.C. resistance of power
transformers and other electrical devices
5897
High Current Portable Micro-Ohmmeter.
Four terminal measurement. Current 100Amp.
Basic accuracy of 0.2% and an overall resistance range of 0.1 mΩ
to 40 Ω.
5898
High Current Portable Micro-Ohmmeter.4 terminal measurement. Current
200A.
Basic accuracy of 0.2% and an overall resistance range of 0.1 mΩ to 6 Ω.
4167D
Digital Transformer Ratiometer.
Direct Ratio Reading from 1:1 to 9990:1
4167F
Portable Transformer Ratiometer.
Transformation ratio
measurement.
4167P
Portable Transformer Ratiometer.
Large transformers ratiometer.
4167DH
Automatic Transformer Ratiometer.
PC interfaces (RS232; IEEE488; RS385; RS422)
5867F
Portable Quality Tester.
Shunted and shorted turns, Insulation Resistance breakdown.
|
COIL TEST EQUIPMENT
|
|
|
|
|
|
9600
Coil Turns Counter Readout Unit.
9601, 9602, 9603
Coil Turns Counter Platforms.
5863
Shorted Turn Tester.
5867
Portable Quality Tester.
Shunted and shorted turns, Insulation Resistance breakdown.
|
WHEATSTONE KELVIN BRIDGE
|
|
|
QJ23E
Portable Wheatstone Bridge. Resistance
Bridge. Range
1Ω
to 9.999MΩ
0.1 to 0.2 % accuracy
QJ49E
Portable
Precision Resistance Wheatstone Bridge. Range 1Ω
to 1.1111MΩ.
0.05 % accuracy
QJ31E
Portable Resistance Wheatstone Kelvin
Bridge. Range 10Ω
to 1MΩ
(Wheatstone)
0.0001W to 100W
(Kelvin) 0.1
% accuracy.
QJ42E
Portable
Resistance Double Wheatstone Kelvin Bridge. Range
0.0001Ω to 11Ω.
Accuracy typically 1.0%.
QJ57E
Portable
Resistance Precision DC Kelvin Bridge. Range 10-8Ω to 1111.1Ω.
Accuracy 0.03%
|
SPECIALIST ELECTRONICS EQUIPMENT
|
|
|
|
5762
High Resistance Cable Fault locator.
5762N
High Resistance Cable Fault locator.
|
SUBMARINE CABLE TEST
EQUIPMENT
|
|
|
5902 Long
Haul Submarine Cable Test Set
5930, 5931
Submarine Cable Survey System
5910
Portable Short haul Submarine Cable Test Set
5910R
Rack Mount Short haul Submarine Cable Test Set
5915
Electroding Generator
5916
Electroding Detector
5917
Beach Probe
5918
Battery Powered Portable Electroding Detector
5901C
Submarine Cable DC Test Set
5941
Cable Termination Unit
5906A, 5906B Standard for the calibration of Model 5902 Submarine Cable
Test Set
|
|
|