  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

CURRENT SHUNT AIR COOLED  


4638 Current Shunt Air Cooled.
The Type 4638 Current Shunt Air Cooled Precision shunts cover the range 1.5 to 2,000 Amperes and were designed to comply with the E.S.M. Act. 

Current Shunt. Air Cooled Precision Shunt

Type 4638 Current Shunt Air Cooled
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

Current Shunt Limit of Error 

The Type 4638 current shunts having rated values up to 100 Amperes are calibrated to maintain resistance within 0.03% for any current up to full rated current. 
Between 100 and 2,000 Amperes they will keep within 0.05% for any current up to their full rating. 

Current Shunt Stability 

The stability of these shunts under steady current conditions is better than 0.01%. Their stability with time is of the same order. 

Current Shunt Thermal Errors 

Errors due to thermal E.M.F.s are less than 0.01% of the Volt drop with full rated current; and under zero current conditions will be a few micro Volts only.

Current Shunt Specification

Current
Amperes
Resistance
Ohms
Volt Drop
Volts
Wattage
Watts
Dimensions
Millimeters (approx.)
1.5 1.0 1.5 2.25 230 x 100 x 100
5 0.2 1.0 5 410 x 100 x 100
15 0.1 1.5 23 410 x 130 x 110
15 0.01 0.15 2.25 230 x 130 x 110
50 0.01 0.5 25 280 x 130 x 130
50 0.02 1.0 50 580 x 130 x 140
75 0.002 0.15 11 500 x 155 x 110
150 0.01 1.5 225 860 x 255 x 180
150 0.001 0.15 2.5 500 x 255 x 110
300 0.001 0.3 90 835 x 155 x 200
500 0.0002 0.1 50 410 x 155 x 155
750 0.0002 0.15 110 700 x 210 x 200
1000 0.0001 0.1 100 450 x 210 x 260
1500 0.0001 0.15 225 675 x 210 x 260

 