  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

PRECISION SHUNT STANDARD


4640 Air Cooled Precision DC Shunt Standard.
The 4640 range of Air Cooled Precision DC Shunts offers good accuracy at low cost. 

Available in four resistance values and a range of Full Load operating currents from 50 Amperes to 1,000 Amperes. These instruments are manufactured from selected Manganin, specially heat treated for low temperature coefficient and long term stability. The instruments are constructed using a non-metallic base board with the elements protected by a mesh cover allowing good air flow to cool the instrument. 

Air Cooled Precision DC Shunt

Air Cooled Precision Shunt Standard
Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

Air Cooled Precision DC Shunt Standard specification

0.01Ω - 50 Amperes Accuracy of Adjustment Nominal value ±0.1%
Measurement Uncertainty Tinsley "In House" ±0.01%
AC-DC Transfer Error DC - 60Hz ±0.005%
Load Coefficient 1 Amp to 50 Amp ±0.01%
0.001Ω - 150 Amperes Accuracy of Adjustment Nominal value ±0.5%
Measurement Uncertainty Tinsley "In House" ±0.02%
AC-DC Transfer Error DC - 60Hz ±0.005%
Load Coefficient 5 Amp to 150 Amp ±0.01%
0.002Ω - 500 Amperes Accuracy of Adjustment Nominal value ±1%
Measurement Uncertainty Tinsley "In House" ±0.1%
AC-DC Transfer Error DC - 60Hz ±0.005%
Load Coefficient 5 Amp to 500 Amp ±0.02%
0.0001Ω - 1000 Amperes Accuracy of Adjustment Nominal value ±1%
Measurement Uncertainty Tinsley "In House" ±0.01%
AC-DC Transfer Error DC - 60Hz ±0.005%
Load Coefficient 10 Amp to 1000 Amp ±0.05%

 

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.