DIGITAL
MICRO-OHMMETER MODEL 5891 |
|
|
|
Digital Micro ohmmeter 0.1
µΩ
to 26 kΩ
with accuracy 0.01% |
|
|
5891 Digital
Micro ohmmeter.
Contact resistance
measurement with or without voltage limits (20 mV or 50 mV);
Ground continuity and cable resistance measurements;
Inductive resistance measurements in transformers, alternators,
etc.;
Quotient measurements using a current source and external resistance
standard.
Versions available:
- 5891-1: Basic model (power supply and RS 232).
- 5891-2: Basic model with battery and charger.
- 5891-3: Basic model with IEEE-488 interface.
- 5891-4: Basic model with battery, charger and IEEE-488 interface.
|

5891 micro ohmmeter |
-
Languages available:
English, French,
German, Spanish, Italian.
-
22-key pad covering all
operating and
programming functions.
-
Audible warning (beep) of
any incorrect
operation when programming.
-
Display of error messages in
case of overload,
overrange or incorrect connections.
-
Measurement terminals
duplicated on rear for
rack mount operation.
|
|
|
|
|
-
Direct reading of measurement
and units:
µΩ,
mΩ,
Ω,
kΩ,
%, °C.
-
18 measurement ranges
-
Selection of the measurement
current
|
Three operating modes: . direct current (except with 10 A range), . pulsed current, . alternate current (current flow inversion). - Relative mode value read-out (DR or DR/R). - Programming directly by metal type or by temperature coefficient offers the following advantages: . automatic heat measurement of the component under test; . automatic compensation of its temperature, either by program or by
measurement using a platinum probe. - The RS 232-D or IEEE-488 interfaces allow programming, measurement
processing and unit calibration from a computer as well as
measurement output to a printer. - Measurement storage on request (1 000 values max.) with min, max.
and average values displayed or sent to the interfaces.
|
|
Specifications
|
|
Accuracy |
|
Rated Voltage drop |
Measurement current |
|
External |
10 to 1 A |
100 mA |
| 20 mV |
0.05%+5 |
0.05%+3 |
0.05%+3 |
| 200 mV |
0.05%+3 |
0.05%+2 |
0.05%+2 |
| 2.0 V |
0.05%+1 |
0.05%+1 |
0.05%+1 |
|
|
|
|
Internal Current |
|
Range
|
Resolution |
Rated Voltage drop |
|
Measurement Current |
| 10A |
1A |
100mA |
10mA |
1mA |
100µA |
|
2.0 mΩ
|
0.1µΩ |
20 mV |
|
|
|
|
|
|
20 mΩ
|
1µΩ |
200 mV |
20 mV |
|
|
|
|
|
200 mΩ
|
10µΩ |
2 V |
200 mV |
20 mV |
|
|
|
|
2 Ω
|
100µΩ |
|
2 V |
200 mV |
20 mV |
|
|
|
20 Ω
|
1mΩ |
|
|
2 V |
200 mV |
20 mV |
|
|
200 Ω
|
10mΩ |
|
|
|
2 V |
200 mV |
20 mV |
|
2.0 kΩ |
100mΩ |
|
|
|
|
2 V |
200 mV |
|
20 kΩ |
1Ω |
|
|
|
|
|
2 V |
|
|
|