TECHNICAL DATA |
Voltage
measuring
ranges U*
Nominal value /V
Maximum trms value /V
Maximum peak value for full scale /V
Input impedance |
| |
3
3.6
6.25
>4.5MΩ |
6
7.2
12.5
<3pF |
12.5
14.4
25 |
25
30
50 |
60
60
100 |
130
130
200 |
250
270
400 |
400
560
800 |
600
1000
1600 |
1000
1000
3200 |
|
|
|
Current measuring ranges
I*
Nominal value /A
Maximum trms value /A
Maximum peak value for full scale /A
Input impedance |
| |
20m
37m
59m |
40m
75m
117m |
80m
150m
234m |
150m
300m
469m |
300m
600m
938m |
600m
1.25
1.875 |
1.2
2.5
3.75 |
2.5
5
7.5 |
5
10
15 |
10
20
30 |
20
32
60 |
32
32
120 |
|
| |
=============
560mΩ |
=============
68mΩ |
=============
8.2mΩ |
=============
1mΩ |
|
|
Current
measuring ranges IHF*
Nominal value /A
Maximum trms value /A
Maximum peak value for full scale /A
Input impedance |
| |
150m
225m
325m
0.1Ω |
300m
450m
650m
|
600m
900m
1.3 |
1.2
1.8
2.6 |
|
|
|
|
|
Sensor inputs
USensor,ISensor
Nominal value /V
Maximum trms value /V
Maximum peak value for full scale /V
Input impedance |
|
30m
37m
63m
100kΩ |
60m
75m
125m
34pF |
120m
150m
250m |
250m
300m
500m |
500m
600m
1 |
1
1.2
2 |
2
2.5
4 |
4
5
8 |
|
|
| Measuring
accuracy |
Measuring
Accuracy |
±(% of
measuring value + % measuring range) |
| DC |
0.05Hz…45Hz |
45Hz…65Hz |
65Hz…3KHz |
3kHz...15kHz |
15kHz...100kHz |
100kHz...1MHz |
1MHz...10MHz |
| USensor 30mV...4V |
0.02+0.06 |
0.015+0.03 |
0.01+0.02 |
0.15+0.03 |
0.03+0.06 |
0.2+0.4 |
0.4+0.8 |
f/MHz*0.7+f/1MHz*1.5 |
| ISensor 30mV...4V |
0.02+0.06 |
0.015+0.03 |
0.01+0.02 |
0.15+0.03 |
0.03+0.06 |
0.2+0.4 |
0.4+0.8 |
f/MHz*0.7+f/1MHz*1.5 |
|
Accuracies based
on:
1. sinusoidal voltage and current 4. definition of power
range as the product of
2. ambient temperature 23 °C current and voltage range, 0 ≤
IλI ≤ 1, (λ=Power factor=P/S)
3. warm up time 1h 5. calibration interval 12 month
4. definition of power range as the product of
current and voltage range, 0 ≤ IλI ≤ 1, (λ=Power factor=P/S)
5. calibration interval 12 month
All other values are derived from the current, voltage and
active power values. Accuracies for derived values depend on
the
functional relationship (e.g. S = I * U, ∆S/S = ∆I/I + ∆U/U) |
| Isolation |
All current and voltage
inputs isolated against each other, against remaining
electronic and against earth (1000V/CATIII) |
|
Synchronization |
The measurement is
synchronized on the signals period. There is a choice to
determine the period from „line“, „extern“,
u(t), i(t) as well as their envelopes, combined with
settable filters . By this very stable readings are
achieved, even at signals of
pulse width modulated frequency inverters and amplitude
modulated electronic ballasts. |
| Harmonic
analysis (option CE Harm) |
Measuring of current and
voltage with evaluation in full compliance with EN61000-3-2 |
| Harmonic
analysis (option Harm100) |
Analysis of current, voltage
and power up to 99th harmonics, in total 100 harmonics
including DC component.
Fundamental in the range from 0.1Hz to 150kHz. By integer
divider (1...128) a new reference fundamental can be created
as to
detect interharmonics. Externally on PC up to 1.5Mhz with
software TERM-L5 |
| Flicker
measuring (option) |
Flicker meter according to
EN61000-4-15 with evaluation in full compliance with
EN61000-3-3 |
| Transients
(option) |
Detecting and recording of
transients >330ns |
| Scope
function (standard) |
Graphical representation of
sampled values versus time |
| Plot function
(standard) |
Time diagram of max. 4
readings, minimal resolution 50ms, respectively 10ms in 50Hz
half-wave (flicker) mode |
| Star delta
conversion (option) |
Sums and differences between
channels on sample basis |
Computer
interfaces
Remote control
Output data
Transfer rate |
RS232 (standard) and
IEEE488.2 (option), only one interface can be used at the
same time,
additional USB (option) and Ethernet (option) available.
All functions can be remote-controlled, keyboard lock for
measuring parameters
Output of all readings, data formats BIN/ASCII, SCPI command
set
RS232: max.115200 Baud, IEEE488.2: max. 1MByte/s |
| Floppy drive
(standard) |
3.5’’, 1.44MB |
| Printer
interface (standard) |
Parallel PC-Printer
interface with 25-pin SUB-D socket, printing measuring
values, tables and graphics
to matrix, inkjet or laser printers |
| Processing
signal interface (option) |
2 x 25 pin SUB-D socket
with:
• 8 analog inputs for process magnitudes (16Bit, ±10V)
• 8 analog outputs (16Bit, ±10V)
• 8 digital inputs
• 8 digital outputs
• 2 input for frequency (0.1Hz...500kHz) and rotation
direction
• in- and outputs are isolated against other electronics
(test voltage 500V) |
Other data
Dimensions
Weight
Protection class
Electromagnetic compatibility
Protection system
Operating/storage temperature
Climatic class
Power supply |
• Bench case,
W 433mm x H 147mm x D 400mm
• Accessories: brackets for 19'' rack, 84PU, 3HU, D 400mm
about 12kg
EN61010 (IEC61010, VDE0411), protection class I, overvoltage
category III
EN50081, EN50082
IP20 in accordance to DIN40050
0...40°C, -20...50°C
KYG in accordance to DIN40040
85...264V, 47...440Hz, about 100W |
LMG500
application software
TERM-L5
PQA
SYS61K-3-SOFT |
(Name of software is equal
with Part No. Please request detailed data sheets)
Individual configuration of measurement, using all features
of the LMG500, spectral analysis, remote of LMG500
Software especially designed for power quality analysis
(e.g. EN50160), easy configuring of measurement in a few
steps
Control and evaluation software for test systems of
harmonics and flicker according to EN61000-3-2/-3 |