SINGLE THREE PHASE POWER ENERGY ANALYZER
TM39 Single to 3 Phase Power and Energy Analyzer

TM39 Single or Three Phase Power Energy Analyzer
TM39 Single or Three Phase Power Energy Analyzer for monitoring power and energy.
The desk-top power and energy meter TM39 Single or Three Phase Power Energy Analyzer may be used for representation and recording of energy, power, voltage and current in 3- and 4wire 3phase systems.
With full 4-quadrant measurement capability, all powers and energies are displayed with the correct sign.
Using a 3 line LCD display, both total 3-phase and per phase values (current, voltage, power and power factor) can be displayed. The current and voltage inputs are suitable for direct measurement
in 230/400V low voltage systems.



Power Energy Analyzer
  • Measures voltage, current, power,
    power factor, energy etc.

  • Isolated current measurement inputs

  • Absolutely gap-free measuring process

  • Limit monitoring

  • Programmable analog output

  • PC interfaces RS232,
    RS422/485 (MODBUS), USB

  • Backlighted LCD

  • Ergonomic user friendly interface

  • LabVIEW driver

For price and info please email sales@hotektech.com or call 253-927-6186 ext. 1

Related Instruments Power Analyzers
Power Converters

Digital Multimeters
Clamp-On Meters

The accuracy of power and energy measurements are rated by classes, which are defined in standards like IEC1036, IEC1268. These standards set limits for permissible variation depending
on level, power factor and others. Class 1 means an accuracy of ±1% of the displayed values.

Specification

Measurement inputs
Voltage
Current
Frequency range
Harmonics

400VLL/230VLN, 3 Ø, 3- or 4-wire (110VLL/63VLN optional), operating range 50% to 120% Un
5A for transformers (1A or 25A optional), operating range 0.2% to 120% In
45-65Hz (fundamental)
Up to 20th.
Display
Display Type
Display Format
Digit height

Super twist LCD with LED-Backlight
2 rows of 4 digits and legends for units etc. plus 1 row with 6 digits
12.5mm (4mm legends)
Accuracy
W, kWh
VA, kVAh
var, kvarh
V, A
PF (power factor)
Frequency

Class 1 IEC1036
Class 1
Class 2 IEC1268
±0.2% measuring range or ±1% measuring value ±1 digit, the smaller deviation is valid
±0.2
0.002Hz, ±1 Digit
Auxiliary supply 230V(110V optional) ±15%, 6VA, fully isolated
General
Temperature
Humidity
Memory
Environment
Safety
EMC

Operating -10°C to +55°C, Storage -25°C to +70°C
Operating <75% , non condensing
15 years in event of power failure
IP20 according to DIN 40050
EN61010 (IEC61010, VDE0411), Protection Class I
EN61000 (IEC61000), EN50081, EN50082
Enclosure
Dimensions, Weight

Desk-top case, 248mm x 138mm x 253mm (WxHxD, without handle), approx. 2.6kg
Options
Output relays for pulse or alarm
Type
Pulse programming
Alarm programming
Isolation


2 normally open, contact rating 50V, 150mA, 5W AC/DC max.
Programmable, register, rate and duration
Programmable, measurement value (kW, kVA etc.) with limit and delay time
2.5KV to circuit, 50V relay A to relay B
Interface
Address range, Baud rate
Isolation
RS422 or RS485 multidrop (RS232 alternative), protocol MODBUS, RTU with CRC
1-247 programmable, up to 127 meters (247 with repeater), 2400 to 19200Bd programmable
2.5kV to measurement circuit
Dual analogue outputs
Type, Output
Input range
Scaling
DC-Supply
Isolation
Isolated DC current output, 4-20mA or 0-16mA selectable
Link to one of the actual measuring values
Full scale at 50% to 200% of maximum input
External loop, 24VDC ±6V, also internal with 18VDC
2.5kV to circuit, 50V output to output
TM39 version
with CEE-Plug und CEE-Socket
• Easy to install
• Direct wiring into the supply line

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.

[Home] [Top] [Distribution] [Contact Us]