SINEAX U 539 AC Voltage Transducer Transmitter
Sineax AC Voltage Transducer Measuring transducer for the transformation of sinusoidal or distorted alternating current, with
power supply terminal.
Measurement method: rectifier process.
Measurement input: alternating voltage sinusoidal, arithmetic mean value measurement,
effective value calibration
Housing for top-hat rail mounting.
Certifications: CSA, GL (Germanischer Lloyd)
Sinusoidal Input
Available as Measuring Source
Powered to 230 V 24-60 VAC/VDC or
85-230 VAC/VDC Powered
Input:0-50 V to 0-600 V 50/60 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA,
0-1 V to 2-10 V
AC Voltage Transducer Transmitter
Model | Description |
---|---|
SINEAX U 539 | AC voltage Transducer, 0-500 VAC input, V or mA output |
SINEAX U 543 AC Voltage Transducer Transmitter
Sineax AC Voltage Transducer Measurement method:
Rectifier process.
Measurement input: alternating voltage, sinusoidal, arithmetic mean value measurement,
effective value calibration.
Power supply: without power supply terminal (self-powered), less wiring expense.
Housing for top-hat rail mounting.
Certifications: CSA, GL (Germanischer Lloyd)
Standard as marine version per Lloyds Register of Shipping
Sinusoidal Input
Powered from Measuring Source
Input:0-20 V to 0-600 V 50/60 Hz
Output:
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V
AC Voltage Transducer Transmitter.
Model | Description |
---|---|
SINEAX U 543 | AC voltage Transducer, 0-500 VAC input, V or mA output. |
SINEAX U 553 True RMS AC Voltage Transducer
SINEAX U 553 RMS Voltage Measuring transducer for the transformation of sinusoidal or distorted alternating voltage -
with power supply terminal.
Measurement method: logarithmic process.
MMeasurement input: alternating voltage, sinusoidal or distorted, true RMS value measurement.
Sine, Rectangular or Distorted Wave Forms
Special Version to Allow Zero Offset
24-60 VAC/VDC or 85-230 VAC/VDC Powered
Input:0-20 V to 0-690 V 50/60 or 400 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V
UU 553 True RMS AC Voltage Transducer
Model | Description |
---|---|
SINEAX U 553 | AC voltage Transducer, true RMS, 0-690 VAC input, V or mA output. |
SINEAX U 554 True RMS AC Voltage Transducer
Measuring SINEAX AC voltage transducer for the conversion of sinusoidal or distorted alternating voltage into an output signal
which is proportional to the measured value.
Depending upon the variant, the crucial portion of the measuring range can be extended at the beginning
or the end (various characteristics).
The less crucial or non-crucial portion is suppressed.
Housing for top-hat rail mounting.
Certifications: CSA, GL (Germanischer Lloyd)
Sine, Rectangular or Distorted Wave Forms
Special Version to Allow Zero Offset
24-60 VAC/VDC or 85-230 VAC/VDC Powered
Input:0-20 V to 0-690 V 50/60 or 400 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V
U 554 True RMS AC Voltage Transducer
Model | Description |
---|---|
SINEAX U 554 | AC voltage Transducer, true RMS, 0-690 VAC input, V or mA output. |