Toll Free: 866-436-2430                     Email: sales@hotektech.com

 
 
Instruments, calibrators, standards, analyzers, dataloggers. analyzers
 
  Test measurement instrumens. Analytical instruments, ph meters, dissolved oxygen meter, hygrometer, salinity meter, weather instruments. Power analyzers, Gas combustion analyzer, Electronic load, Harmonic analyzer. Pressure calibrator, deadweight tester, temperature calibrator, current loop calibrator. Temperature datalogger, humidity datalogger, barometric pressure datalogger, wireless datalogger. Hygrometer, humidity datalogger, HVAC instrument, humidity controllers transmitters. Candela meter, Luminance meter, Radiometer, Albedometer, Luminance transmitter. Cable detectors, coil tester, insulation resistance, resistance bridge, tachometers. Digital multimeter, clamp on meter, amperometer, current meter, high line voltmeter, phasing sequence meter.  
  Resistance bridge, ohmmeter, insulation resistance meter, multimeters, milli ohmmeter, micro ohmmeter, megohmmeter. Manometer, Pressure gauge, deadweight tester, pressure pump, vacuum pump, pressure calibrator. Simulator, Calibrator, resistance standard, resistor decade, inductance standard, thermometry standards. Thermometry bridge, precision thermometer, infrared thermometer, temperature calibrator, dry block calibrator. Current transmitter, Luminance transmitter, energy transmitter, pressure transmitter, temperature transmitter.  
 

Search  

 
 
 

PC-MAXI PC ISA INTERFACE CARD


The PC-MAXI ARINC 429 Interface Card has four module sites available for interfaces. It can support either similar or different interface types. So it is possible to have an ARINC429 2 transmit, 2 receive Mini-Module mounted on one site with a PANAVIA Mini-Module mounted on a second site, thus providing a mixed ARINC429 and PANAVIA solution.

Our Price: Contact us for pricing
Phone: 253-927-6186
866-318-6186
Fax: 253-927-6189
email: sales@hotektech.com

The PC-MAXI (Multi - Adapter - eXtender - Interface) provides by far the most flexible platform for today's demanding test and OEM applications. 
The card features a common clock for all time tagging registration of data and single generation of PC interrupts from the various modules fitted to the card and provides a common master platform for all types of data bus interface that need to be interfaced to a PC.

The card is a full length PC ISA interface card designed to accept up to four standard YED Mini-Module Interface cards. 
Support for ARINC419/429/575, PANAVIA, NMEA0183 and opto-coupled discrete I/O are currently available. 
For example, the card shown is a 8 transmit and 8 receive independent (non-multiplexed) ARINC429 (16) channels.
In addition to this special interface application modules can be designed to order.
Supplied with 'C' driver library source code.
Interface Configurations and Functional Characteristics

A common clock is available to all Mini-Modules, thus providing synchronized operation of features such as time tag registers. Interrupts generated by each Mini-Module are handled by the on card Interrupt Control Logic, which in turn is responsible for generating the PC interrupt. 
An Interrupt Status Register identifies the interrupting Module.

The card is configured as a 16 bit ISA interface and occupies the D0000 to DFFFFH PC Memory page space. Interrupts provided are 3,4,5,6,7,10,11 and 12.

Product Specification PC-MAXI
  • 16 bit Full length PC ISA interface
  • PC Memory mapped addressing.
  • On board clock generation, PC Interrupt Control Logic and PC Memory decoding
  • Single D37 PC Bracket mounted interface connector
  • Double expansion by use of additional card in Slave Mode
  • Accepts up to four YED Mini-Module Interface products.

Interfaces include: ARINC419/429/575, PANAVIA, NMEA0183, RS422, I/O.

Interface Module Types MINI-MODULES

MINI-429/T2/R2
The MINI-429/T2/R2 ARINC 429 Interface
comprises of two independent transmitter
channels that act as Bus Traffic Simulators
and two independent receiver channels that
provide advanced Monitor and Analyzer functions. 
The functions on the four channels are available concurrently at full performance level. 
In addition to this the card also contains, a microprocessor,
a time tag register, 
Opto-coupled inputs, Auto-Rx Speed Adoption, Data Acquisition FIFO's, and Dual Port. 

The specification is similar to the PC4/T2/R2 PC ISA card.
MINI-429/T4

The MINI-429/T4 ARINC 429 Interface comprises of four independent transmitter channels that act as Bus Traffic Simulators. The functions on the four channels are available concurrently at full performance level. 
The card contains a microprocessor, Dual Port and ARINC429 line drivers. 
The specification is similar to the PC4/T4 PC ISA card.

MINI-429/R4

 

The MINI-429/R4 ARINC 429 Interface comprises of four independent receiver channels that provide 
advanced Monitor and Analyzer functions. 
The functions on the four channels are available 
concurrently at full performance
level. 
In addition to this the card also contains, a microprocessor, a time tag register, Opto-coupled inputs, Auto-Rx Speed Adaption, Data Acquisition FIFO's, and Dual Port. 
The card will filter from all 256 label/SDI combinations. The specification is similar to the PC4/R4 PC ISA card.
MINI-NMEA0183

The MINI-NMEA0183 Interface comprises of a single channel NMEA0183 transmitter and receiver circuit. All received data is time tagged and written to the on board data acquisition FIFO’s in the order of arrival. Sentences can also be loaded and transmitted from the card at varying repetition rates at 4800 baud.

‘C’ source code driver libraries are also available for OEM’s that wish to implement their own software.

 

Please email sales@hotektech.com or call 253-927-6186 if you are interested in a purchase, or
  need additional information.


[Home] [Top] [Distribution] [Contact Us]