Avionic Analyzers and Data Converters
The DATAIR-400/M3(V2) is the next generation of the previous DATAIR-400/TR ARINC 429 handheld Tester. The DATAIR-400/M3(V2) is aimed at providing the user with an easy to use first line diagnostic tool for testing and troubleshooting ARINC 429 avionics systems.
The DATAIR-400/M3+ ARINC 429 Tester is a Hand Held unit that comprises an 8 line by 21 character backlit LCD, an alphanumeric keypad, a microprocessor controlled ARINC 429 receiver, transmitter board with a detachable rechargeable battery pack.
The DATAIR-1500/M3 hand held data Tester performs a simple first line diagnostics and real time data analysis of the MIL-STD-1553B data bus. It allows the user to connect a MIL-STD-1553B data bus and conveniently view the active 1553 traffic on the bus.
Four transmitter and four receiver ARINC 429/575 channels. Easy-to-use full function ARINC 429/575 interface enabling the user to communicate with, simulate, test and monitor ARINC 429 equipment and systems via their Desktop or Laptop computer.
The value of the ARINC 429 label, the SDI and the SSM are configurable by the user via miniature DIP switches located on the printed circuit board (PCB). The transmission rate (bit rate and repetition rate) of the ARINC 429 word can also be configured via DIP switches.
This ARINC 429 to NMEA 0183 converter is in use by many companies who have a requirement to extract navigational data from an ARINC 429 data bus and translate it onto an RS232 or RS422 serial data bus.
This NMEA 0183 to ARINC 429 converter is in use by many companies who have a requirement to extract navigational data from a standard NMEA 0183 data stream and translate it onto the ARINC 429 data bus.
This ARINC 429 to 0-10Vdc Output converter is in use by many companies who have a requirement to extract a specific ARINC 429 parameter from a user selectable Label and translate it into a 0-10VDC output.
This ARINC 429 to three 0-10Vdc Outputs converter is employed where there is a requirement to extract data from up to three separate user specified ARINC 429 Labels on the same databus and translate it into three separate 0-10VDC outputs.
This converter consists of two ARINC 429 receiver channels that each drive three relay contacts – six relays in total. Each receiver monitors Label nnn ARINC 429 for a specific bit pattern within them.
An enhanced version of our popular ARINC 429 to 2-Channel Relay converter, except that this converter contains 8 discrete volt-free relay contacts with additional options.
Data Translator Protocol Converter is a bi-directional converter. It translates specific received ARINC429 data onto an RS232 databus and also translates specific received RS232 data onto the ARINC429 databus.