Phone: 253-927-6186
 Email: sales@hotektech.com
Home > Transducers > Sineax AC Voltage Transducer

SINEAX U 539 AC Voltage Transducer Transmitter

Sineax AC Voltage Transducer Measuring transducer for the transformation of sinusoidal or distorted alternating current, with power supply terminal.
Measurement method: rectifier process.
Measurement input: alternating voltage sinusoidal, arithmetic mean value measurement, effective value calibration
Housing for top-hat rail mounting.
Certifications: CSA, GL (Germanischer Lloyd)

U539 Sineax transducer 

Sinusoidal Input
Available as Measuring Source
Powered to 230 V 24-60 VAC/VDC or
85-230 VAC/VDC Powered

Input:0-50 V to 0-600 V 50/60 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA,
0-1 V to 2-10 V

AC Voltage Transducer Transmitter

Model  Description 
SINEAX U 539 AC voltage Transducer, 0-500 VAC input, V or mA output

SINEAX U 543 AC Voltage Transducer Transmitter

Sineax AC Voltage Transducer Measurement method: Rectifier process.
Measurement input: alternating voltage, sinusoidal, arithmetic mean value measurement, effective value calibration.
Power supply: without power supply terminal (self-powered), less wiring expense.
Housing for top-hat rail mounting. Certifications: CSA, GL (Germanischer Lloyd)
Standard as marine version per Lloyds Register of Shipping

 Sinex U553 AC voltage transducer

Sinusoidal Input
Powered from Measuring Source

Input:0-20 V to 0-600 V 50/60 Hz
Output:
0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

AC Voltage Transducer Transmitter.

Model  Description 
SINEAX U 543  AC voltage Transducer, 0-500 VAC input, V or mA output.

SINEAX U 553 True RMS AC Voltage Transducer

SINEAX U 553 RMS Voltage Measuring transducer for the transformation of sinusoidal or distorted alternating voltage - with power supply terminal.
Measurement method: logarithmic process.
MMeasurement input: alternating voltage, sinusoidal or distorted, true RMS value measurement.

 U553 true rms ac voltage transducer.

Sine, Rectangular or Distorted Wave Forms
Special Version to Allow Zero Offset
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-20 V to 0-690 V 50/60 or 400 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

UU 553 True RMS AC Voltage Transducer

Model  Description 
SINEAX U 553  AC voltage Transducer, true RMS, 0-690 VAC input, V or mA output.

SINEAX U 554 True RMS AC Voltage Transducer

Measuring SINEAX AC voltage transducer for the conversion of sinusoidal or distorted alternating voltage into an output signal which is proportional to the measured value.
Depending upon the variant, the crucial portion of the measuring range can be extended at the beginning or the end (various characteristics).
The less crucial or non-crucial portion is suppressed.
Housing for top-hat rail mounting. Certifications: CSA, GL (Germanischer Lloyd)

U554 true rms ac voltage transducer. 

Sine, Rectangular or Distorted Wave Forms
Special Version to Allow Zero Offset
24-60 VAC/VDC or 85-230 VAC/VDC Powered

Input:0-20 V to 0-690 V 50/60 or 400 Hz
Output:0-1 mA to 0-20mA
1-5 mA to 4-20 mA
0-1 V to 2-10 V

U 554 True RMS AC Voltage Transducer

Model  Description 
SINEAX U 554  AC voltage Transducer, true RMS, 0-690 VAC input, V or mA output.
We accept
  • American Express
  • Master Card
  • VISA
  • Purchase Orders
Company
Hotek Technologies, Inc
tel: 253-927-6186
sales@hotektech.com
services@hotektech.com