SINEAX M 561 Power & Current Transducer
SINEAX M 561 is a programmable Power & Current transducer with a RS 232 C interface.
M 561 supervises 1 variable
(input) which is available on an analog output signal.
Input and
output are electrically isolated.
Rated current: 1..6A.
Rated voltage: 57,7...400V (P-N) rsp. 100...693V (L-L)
Universal analog outputs (programmable).
High accuracy: class 0.5
Sine, Rectangular or Distorted Wave Forms
One Analog Outputs
Measures any Three: P, Q or S, I ~,
U ~ (RMS), cos, sin j, LF, PF, QF, f
Data Logging Function
RS 232 PC Programming Interface
24-60 VAC/VDC or 85-230 VAC/VDC Powered
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 57-400 V
phase-to-neutral 100-693 V phase-to-phase 50/60 Hz
Output:0-20 mA, 4-20 mA 0-1 V to 0-10 V 2-10 V
SINEAX M 561 Power & Current programmable transducer
Model | Description |
---|---|
SINEAX M561 | Power & Current Programmable transducer, 1 analog output, RS-232 |
SINEAX M 562 Power & Current Transducer
M 562 ower & Current Transducer measure 2
3 variables simultaneously and generate 2 electrically
isolated analog output signals.
The transducer is also equipped with an RS 232 serial interface to which a PC with the corresponding
software can be
connected for programming or accessing and executing useful
ancillary functions.
Rated current: 1..6A.
Rated voltage: 57,7...400V (P-N) rsp. 100...693V (L-L)
Universal analog outputs (programmable).
High accuracy: class 0.5
Sine, Rectangular or Distorted Wave Forms
3 Analog Outputs
Measures any Three: P, Q or S, I ~,
U ~ (RMS), cos, sin j, LF, PF, QF, f
Data Logging Function
RS 232 PC Programming Interface
24-60 VAC/VDC or 85-230 VAC/VDC Powered
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 57-400 V
phase-to-neutral 100-693 V phase-to-phase 50/60 Hz
Output:0-20 mA, 4-20 mA 0-1 V to 0-10 V 2-10 V
SINEAX M 562 power current transducer
Model | Description |
---|---|
SINEAX M562 | Power current Multi-transducer, CT inputs, 2 analog outputs, RS-232 |
SINEAX M 563 Power & Current Transducer
Current Transducer for simultaneously acquiring 3 freely selectable measurands of an electrical power system.
Three analog outputs, RS232.
Programmable application (type of electrical system)
Rated current: 1..6A.
Rated voltage: 57,7...400V (P-N) rsp. 100...693V (L-L)
Universal analog outputs (programmable).
High accuracy: class 0.5
Sine, Rectangular or Distorted Wave Forms
3 Analog Outputs
Measures any Three: P, Q or S, I ~,
U ~ (RMS), cos, sin j, LF, PF, QF, f
Data Logging Function
RS 232 PC Programming Interface
24-60 VAC/VDC or 85-230 VAC/VDC Powered
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A 57-400 V
phase-to-neutral 100-693 V phase-to-phase 50/60 Hz
Output:0-20 mA, 4-20 mA 0-1 V to 0-10 V 2-10 V
M563 3 analog outputs transducer
Model | Description |
---|---|
SINEAX M563 | Current Transducer, CT inputs, 3 analog outputs, RS-232 |
SINEAX P 530 Active Power & Q 531 Reactive Power Transducer
Reactive Power Measuring transducer for the conversion of active power in single phase alternating current or
3-phase systems with balanced or unbalanced load.
A load-independent direct current or direct voltage is used as an output signal, which is proportional to
the measured active power value.
Measuring method: TDM method
Measurement inputs: sinusoidal nominal input current 1...6 A and nominal input voltage 100...690 V(L-L)
3-Phase with Balanced or Unbalanced Load
Sinusoidal Input Available as Measuring Source
Powered to 230 V 24-60 VAC/VDC or
85-230 VAC/VDC Powered
Input:0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A
100-690 V 50/60 Hz
Output:0-1 mA to 0-20mA 1-5 mA to 4-20 mA
1 mA to 20 mA 0-1 V to 2-10 V, to 10 V
Active Power Transducer
Model | Description |
---|---|
SINEAX P530 | SINEAX Active Power Transducer |
SINEAX Q531 | SINEAX Reactive Power Transducer |