Gemini 550 Dry Block Calibrator. Temperature range 35°C to 550°C
Gemini 700 Dry block Temperature Calibrator. Temperature range 50°C to 700°C
High Capacity Dry Block Calibrators.
The Gemini Dry block range differs from our other dry blocks with an enormous well capacity of more
than 2.5” While still offering all the advantages you’ll find in other calibrators the Gemini has been designed
to have a large block suitable for more probes.
The Gemini Dry block calibrators are available in two models, the BASIC (B) and the SITE (S).
The B model includes a sophisticated temperature controller with a dual display for Set Temperature and
Dry Block Temperature. The large block has the benefit of higher capacity but with longer heating and
cooling times compared to the fast response models.
GEMINI Dry block Calibrator
Model | Description |
---|---|
550 | GEMINI 550 Dry Block (35°C to 550°C) |
550-SITE | GEMINI 550-SITE Dry Block (35°C to 550°C) |
700 | GEMINI 700 Dry Block (50°C to 700°C) |
700-SITE | GEMINI 700-SITE Dry Block (50°C to 700°C) |
instrument and probe can be calibrated as a system.
High Capacity Block -- Large Calibration volume for many sensors and low loading errors.
Two Operating Ranges -- Fast response from 35°C to 550°C (1022°F) or 50°C to 700°C (1292°F)
Simple To Use -- Outstanding Value for Money!
Windows Software, Computer Interface and a Ramp to Set Point Feature.
Increased resolution of ±0.01 available throughout the range via the PC interface and
from 0.01to +99.99 locally on the auto-ranging front display.
The controller features multi-point block to display correction giving excellent absolute accuracy.
The SITE model has universal sensor input allowing Platinum Resistance Thermometers,
Thermocouples (Types K, N, R, S, L, B, PL2, T, J and E) along with Linear Process Inputs including
4-20mA current transmitters to be displayed on the built-in indicator.
The indicator can be programmed with up to five calibration points to provide high accuracy digital
probe matching. The indicator and controller are both addressable over the communications link.
Model | Gemini 550 & Gemini 700 |
Temperature Range | Gemini 550: 35°C to 550°C
Gemini 700: 50°C to 700°C |
Accuracy | ≤±0.3°C Throughout entire range |
Absolute Stability Over 30 Minutes | ±0.05°C |
Computer Interface | Included with Windows Software |
Cooling Time | Gemini 550: 550°C to 275°C in 35 min.
Gemini 700: 550°C to 60°C in 345 min. |
Heating Time | Gemini 550: 30°C to 550°C in 35 min.
Gemini 700: 50°C to 700°C in 110 min. |
Calibration Volume | Four 8mm pockets, four 19.5mm pockets, |
Standard Block | All 160mm deep |
Display Resolution | 0.01 to 99.99
0.1 100.0 to 700.0 PC can display 0.01 across whole range with the software included |
Indicator Units | °C, °F, °K |
Supply | 110VAC ±10% (50/60 Hz)
Hyperion: 200 Watts Drago: 1000 Watts |
Dimensions | 302mm x 176mm x 262mm (HxWxD) |
Weight | Gemini 550: 18.7 lbs (8.5kg)
Gemini 700: 30.9 lbs (14kg) |