PC10 PC control Power Analyzer Converter measures, computes and transmits all your important power
variables to your computer.
The software lets you select the quantities you want to display on the PC/Notebook monitor.
The settings, such as auto or manual ranging are easily changed and measurements are stored at a
mouse click.
The PC
control Power Analyzer is available in single or three phase versions and combines
an ammeter, voltmeter, wattmeter and a spectrum analyzer in a single light weight package.
PC10 Power analyzer
Model | Description |
---|---|
PC10-1/0.1 | Single Phase PC Power analyzer, 0.1% accuracy |
PC10-1/0.05 | Single Phase PC control Power analyzer, 0.05% accuracy |
PC10-3/0.1 | Three Phase PC control Power analyzer, 0.1% accuracy |
PC10-3/0.05 | Three Phase PC control Power analyzer, 0.05% accuracy |
From the simultaneous and precise voltage and current measurement you can obtain the RMS,
rectified mean, mean, min, max and harmonics through the 99th order.
Particular care has been taken to obtain precise power readings (watts, VA, VAR and power factor) at
highly distorted signals. Other values determined are: frequency, crest- and form factor, THD, Wh, VAh,
VARh, Ah, harmonics of power, harmonics of impedance (magnitude and phase) and line-to-line voltages.
The PC10's combination of high frequency performance, excellent common mode rejection and
simultaneous
measurements is needed for accurate readings on inverter drives, switched mode
power supplies and
ballast lighting equipment.
The current input from 15mA to 40A can be extended to 100A with our option, or you can use your
own Hall
sensor for current measurements up to 20kA. A shunt input for high frequency current viewing
resistors or
current clamps is included.
Measurement accuracy of 0.1% in a compact, light weight instrument is useful
in the laboratory,
in the field and in automatic test systems.
PC10 Power Analyzer Converter | ||
Voltage | Ranges, 8 ranges 1-3-10-sequence; 0.3V, 1V, 3V, 10V, 30V, 100V, 300V, 1000V | |
Frequency range | DC, 0.1Hz-1MHz | |
Crest Factor | 3:1 at 50% full scale (fs) | |
Input Impedance | less than 1MΩ | |
Common Mode - 50Hz/100kHz | 160dB/100dB | |
Standard accuracy 23°
C; rms, mean, rectified mean; 0.3V typical 1Hz-1kHz = ± (0.1% rdg + 0.1% range) DC, 1kHz-10kHz = ± (0.2% rdg + 0.2% range) 10kHz-100kHz = ± (0.3% range + 0.04%/kHz rdg) 100kHz-300kHz = ± (0.3% range + 0.04%/kHz rdg), typical |
Improved accuracy ± (0.05% rdg + 0.07% range ) |
|
Current | 13 Ranges: 1.5mA, 5mA, 15mA, 50mA, 150mA, 500mA, 1.5A, 5A; 1A, 3A, 10A, 30A, 100A | Max. 1A, 5A, 30A, resp. |
Frequency range | DC, 0.1Hz-300kHz | |
Crest Factor | 3:1 at 50% full scale (fs) | |
Common Mode - 50Hz/100kHz | 160dB/120dB | |
Standard accuracy 23°
C; 1A-, 5A-, shunt input 1Hz-1kHz DC, ± (0.1% rdg + 0.1% range) 1kHz-10kHz ± (0.2% rdg + 0.2% range) 10kHz-100kHz ± (0.3% rdg + 0.04%/kHz rdg) 100kHz-300kHz ± (0.3% rdg + 0.04%/kHz rdg) |
Lowest ranges 1.5mA, 15mA 1A typical. Improved accuracy 1Hz-400Hz ± (0.05% rdg + 0.07% range) |
|
Power | 104 ranges corresponding to the products V x A | |
Frequency range | DC, 0.1Hz-300kHz | |
Accuracy 23°
C ±
3°
C 45Hz-65Hz ± (0.1% rdg + 0.01% range) 1Hz-1kHz Add accuracy percentage of current and voltage DC, 1kHz-10kHz +0.04%/kHz PF 10kHz-100kHz |
PF = 0 to ± 0.1 PF = 0 to ± 1 PF = 0 to ± 1 PF = 1 |
|
Frequency | 0.1Hz-400kHz, V triggered; Accuracy ± 0.1% | |
Computed Values |
Accuracy; Reactive Power, Var = ±
(VA² - W²)½; Apparent Power: VA = Arms Vrms; Power Factor: PF = W/VA; Crest Factor: CF = Ap/Arms, Vp/Vrms; Form Factor: FF = At/Arms, Vt/Vrms; Impedance: Z = Vrms/Arms; Total Harm Dist: THD = (Irms² - IFund²)½/Irms |
Add accuracy percentage figures of values involved in computation. |
Integrator | Energy, Charge; Accuracy - Wh, VAh, Varh, Ah; Basic accuracy of integrated quantity. | |
Harmonic Analysis |
Frequency range of fundamental - 2.5Hz-100kHz | |
Range of harmonic | 1-99 | |
Accuracy, Harmonic current and voltage 2Hz-1kHz = ± (0.1% rdg + 0.1% range) 1kHz-10kHz = ± (0.5% rdg + 0.5% range) 10kHz-100kHz = ± (0.7% range + 0.1%/kHz rdg),typical |
||
Options | IEEE-488-2, RS232, Centronics printer output 4 programmable analog outputs, single-, sum-, or average values 4 Analog inputs 0-± 5V, input impedance 200kΩ 4 Analog inputs 0-± 10V, input impedance 200kΩ Rack mounting kit Windows Operating Software (95 - Vista), transformer-motor testing |
0 - ±
5V, accuracy 0.2% 0 - ± 5V, accuracy 0.2% 0 - ± 10V, accuracy 0.2% |