Two channel data logger.
RTR-53 Data logger wireless. Temperature Range 0 to 55 deg C. Humidity Range: 10 to 95% RH.
RTR-53L Data logger wireless. Temperature Range 0 to 55 deg C. Humidity Range: 10 to 95% RH
Large Capacity Battery Type.
The RTR-53 with its standard temperature humidity sensor is able to simultaneously measure and record temperature within a range of 0 to 55°C and humidity within a range of 10 to 95%RH.
The sensor for the RTR-53 has been specially designed to withstand certain amounts of condensation.
The RTR-53 has an IEC water resistance rating of IP-64.
Note:
The main unit is designed for use in environments with an ambient temperature between -40 to 80°C and is water resistant.
RTR-53 Data logger
Model | Description |
---|---|
RTR-53 | Temperature humidity Data logger wireless. |
RTR-53L | Temperature humidity Data logger wireless. |
RTR-53/53L | |
Measurement Channel |
1Temperature and 1 Humidity Channel |
External Temp. Sensor |
0 to 55°C |
External Humidity Sensor |
10 to 95%RH |
Measurement Display Resolution |
0.1°C/1%RH |
Measurement Accuracy |
Avg ±0.3°C ±5%RH (at 25 and 50%RH) |
Recording Interval |
1,2,5,10,15,20,30 seconds / 1,2,5,10,15,20,30,60 minutes Total of 15 choices |
Recording Capacity |
8,000 Readings x 2 Channels |
Recording Mode |
Endless (Overwrite oldest data when capacity is full) / One-time (Stop recording when capacity is full) |
LCD Display Items |
Current Readings / Recording Settings / Battery Life Warning / Over Measurement Range Warning / Amount of Recorded Data |
Power |
Lithium Battery (LS14250(SAFT)) x 1 or AC Adaptor (sold separately) *2 |
Battery Life *3 |
Approximately 6 months |
Wireless Method |
FCC Part 15 Section 249 / IC RSS-210 |
Transmission Range |
Approximately 100m (May vary with conditions) |
Dimensions |
H62mm x W 47mm x D19mm (excluding protrusions / antenna length 20mm) |
Interface |
Wireless Communication / Optical Communication |
Communication Speed |
When downloading data (Wireless) about 2,000 readings per minute [Collection of a full unit of data= about 420 seconds (optical communication= about 160 seconds)] |
Water Resistance *4 |
IP64 (rated for use in daily life) |
Standard Sensor / Input Cable |
TR-3310 (length: Approx.1m) x 1 |
Unit Temp. Resistance |
-40 to 80°C |
Others |
RTR-51/52/52Pt/53: In order to download data via wireless communication, it is necessary to purchase either an RTR-57U, RTR-5W, and/or RTR-50 unit. -For optical communication, TR-50C can also be used for all types of units. |