Flue Gas Analyzer.
330-1 Flue Gas Analyzer. CO, CO2, Pressure, Exhaust Gas, NO, O2, Efficiency.
330-1 Flue Gas Analyzer incl. rechargeable battery and calibration protocol.
The major benefits of the flue gas
analyzer lie in its dialog functions: Instrument diagnosis provides information at the touch of a button about
the qualitative status of functions such as on the level in the condensate trap but also on wearing parts,
for example, the state of the measurement cells.
Maintenance intervals are displayed, making your work easier to plan.
Flue Gas Analyzer.
Model | Description |
---|---|
330-1G LL Kit #1 | 330-1 LL flue gas analyzer, O2-CO |
330-1G LL Kit #1 | Residential Analyzer Kit (with case) |
330-1G LL Kit #2 | Residential Analyzer Kit (with case and printer) |
330-1G LL Kit #4 | NOx Analyzer Kit |
The times in which an analyzer lets the user down belong to the past.
Modular probes, such as ΔT, ΔP,
flue gas are recognized automatically by the analyzer and the measurement results appear
immediately in the menu. The probes have a quick connection function ensuring that all gas paths are
connected correctly. The single cable is rigid, indestructible and saves space.
The particle filter is positioned in the probe handle.
Probe shafts with different lengths and diameters can be easily attached to the probe handle.
Memory | 200 |
---|---|
Display | Graphics display: 160 x 240 pixel |
Storage temperature | -20 to +50 °C |
Operating temperature | -5 to +45 °C |
Weight | 600 g |
Dimensions | 270 x 90 x 65 mm |
Probe type Type K | |
Meas. Range | -40 to +1200 °C |
Accuracy |
±0,5 °C (0.0 to +100.0 °C) ±0,5 % of mv (remaining range) |
Resolution |
0.1 °C (-40 to 999,9 °C) 1 °C (remaining range) |
Probe type CO | |
Meas. Range | 0 to 500 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5% of mv (>100 ppm) |
Resolution | 1 ppm |
Response time | Approx. 35 s |
Probe type CO2 | |
Meas. Range |
0 to 1 Vol. % 0 to 10000 ppm |
Accuracy | ±(50 ppm ±2 % of mv) (0 to 5000 ppm) |
Response time | Approx. 35 s |
Probe type Differential pressure | |
Meas. Range | 0 to 200 hPa |
Accuracy |
±0.5 hPa (0.0 to 50.0 hPa) ±1 % of mv (50.1 to 100.0 hPa) ±1.5 % of mv (remaining range) |
Resolution | 0.1 hPa |
Probe type | |
Meas. Range | -9.99 to +40 hPa |
Accuracy |
±0.02 hPa or ±5 % of mv (-0.50
to +0.60 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±1.5 % of mv (+3.01 to +40.00 hPa) |
Probe type NO | |
Meas. Range | 0 to 300 ppm |
Accuracy |
±2 ppm (0.0 to 40.0 ppm) ±5% of mv (remaining range) |
Reaction time | < 30 s |
Probe type Exhaust gas loss measurement | |
Meas. Range | 0 to 99.9 % |
Resolution | 0.1 % |
Probe type Electrochemical measurement CO | |
Meas. Range | 0 to 4000 ppm |
Accuracy |
±20 ppm (0 to 400 ppm) ±5% of mv (401 to 1000 ppm) ±10% of mv (1001 to 4000 ppm) |
Resolution | 1 ppm |
Probe type Electrochemical measurement NO | |
Meas. Range | 0 to 3000 ppm |
Accuracy |
±5 ppm (0 to 100 ppm) ±5% of mv (101 to 2000 ppm) ±10% of mv (2001 to 3000 ppm) |
Resolution | 1 ppm |
Probe type Electrochemical measurement O2 | |
Meas. Range | 0 to 21 Vol. % |
Accuracy | ±0.2 Vol. % |
Resolution | 0.1 Vol. % |
Probe type Efficiency Measurement (Eta) | |
Meas. Range | 0 to 120 % |
Resolution | 0.1 % |
Probe type | |
Meas. Range | 0 to CO2 max |
Accuracy | ±0.2 Vol. % |
Reaction time t90 | < 40 s |