Phone: 253-927-6186
 Email: sales@hotektech.com
Home > Calibrators > Thermocouple RTD Calibrators > TC-100 Thermocouple Calibrator

TC100 Thermocouple Calibrator

The TC100 Thermocouple Calibrator provides high accuracy source and measurement of ten common thermocouples, as well as mV.
The TC-100's Thermocouple Calibrators accuracy of ± 0.3° C for Type J T/Cs includes all errors, at resolutions of ± 0.01° C or ° F in measure mode and ± 0.1° C or ° F in source mode.
Features including MIN/MAX recall in measure mode, three set points per thermocouple range, a large knob for decade control of the output in source mode, and the ability to accept bare T/C wires in addition to mini-plug inputs, makes the TC-100 thermocouple calibrator an accurate, easy-to-use instrument for all your thermocouple calibration needs.

TC100 Thermocouple Calibrator

Model  Description 
TC100  Thermocouple Calibrator 
includes Protective Sleeve Case, Batteries, Instruction Manual,
NIST Calibration Certificate
TC100 Thermocouple Calibrator
Output Voltage 
Range:  -10 to +75.000 mV 
Resolution:  1 µV 
Accuracy:  ± 0.007 % of reading, ± 10 µV 
Output Impedance:  ≤1 Ohm 
Input Voltage 
Range:  -10 to +75.000 mV 
Resolution:  1 µV 
Accuracy:  ± 0.007 % of reading, ± 10 µV 
Output Impedance:  Input Impedance > 1 MegOhm 
Thermocouple Source/Measure: 
Types:  J, K, T, E, R, S, B, L, U, C 
Range:  mV 
Resolution 
Source:  ± 0.1° C or ° F 
Measure  ± 0.01° C or ° F 
Accuracy: 
± 0.5 ° C; -210 ° C to -100 ° C
± 0.3 ° C; -100 ° C to +1,200 ° C 
± 0.6 ° C; -200 ° C to -100 ° C
± 0.35 ° C; -100 ° C to +1,000 ° C
± 0.5 ° C; +1,000 ° C to +1,372 ° C 
± 0.7 ° C; -200 ° C to -150 ° C
± 0.3 ° C; -150 ° C to +400 ° C 
± 0.5 ° C; -200 ° C to -100 ° C
± 0.3 ° C; -100 ° C to +1,000 ° C 
± 1.8 ° C; 0 ° C to 250 ° C
± 1.0 ° C; 250 ° C to +1,767 ° C 
± 1.8 ° C; 0 ° C to 250 ° C
± 1.0 ° C; 250 ° C to +1,767 ° C 
± 1.7 ° C; 600 ° C to 1,000 ° C
± 1.2 ° C; 1,000 ° C to 1,820 ° C 
± 0.5 ° C; -200 ° C to -100 ° C
± 0.4 ° C; -100 ° C to +900 ° C 
± 0.7 ° C; -200 ° C to 0 ° C
± 0.3 ° C; 0 ° C to +600 ° C 
± 0.4 ° C; 0 to ° C 1,000 ° C
± 0.7 ° C; 1,000 ° C to +1,800 ° C
± 1.2 ° C; +1,800 ° C to +2,316 ° C 
CJC Temperature Offset:  ± 0.05 ° C/° C outside of 23± 5 ° C 
Warm-up Time:  1 minute to specification 
Environmental:   
Operating:  10 ° C to +55 ° C 
Storage:  -20 ° C to +70 ° C 
Power Requirements: 
Battery:  9 Volt alkaline; 006P/ IEC 6F22/ NEDA1604
Optional NiCad
Optional AC adapter/charger 
Mechanical Dimensions:  5.7" x 3.15" x 1.43"
(14.47 cm x 8.00 cm x 3.63 cm) 
Weight:  12 ounces (340 grams) 
We accept
  • American Express
  • Master Card
  • VISA
  • Purchase Orders
Company
Hotek Technologies, Inc
tel: 253-927-6186
sales@hotektech.com
services@hotektech.com
info@hotektech.com